Dental film - Eco 30 - Self Developing IOPA X-Ray Film (50pcs)

Dental film - Eco 30 - Self Developing IOPA X-Ray Film (50pcs)

₹2,125.00 ₹2,500.00 -15%
Product Code: DENTAFLM_IOPA
Availability: In Stock

 Eco 30 - Self Developing IOPA X-Ray Film (50pcs) 

Features:

  • The ECO-30 films come ready packed with a monobath containing both developer and fixer, and so do not require a darkroom.
  • The ECO-30 is intended to provide fast, high-resolution x-rays without the use of a dental processor.
  •  Available as a self-contained packet with a monobath solution in one end and an adult size film in the other, the  ECO-30 x-ray is fully developed in 50 seconds.

  • It is recommended for endodontic and implant procedures, nursing home dentistry, mobile dentistry, late night emergencies, and in case of equipment failure.
  • The developed x-ray can be archived for up to 10 years.

 

Advantages:       

  • Self developing, high defination x-ray fims.

  • No need for developer, fixer and dark room.

  • Ideal standby for RVG clinics in case of malfunction of RVG/computer.

  • Develop X-Ray quickly.

 

 Indications:

  • For  emergencies, surgery check, endodontic and implant procedures.

  • Mobile dentistry, nursing home dentistry, military field conditions, and as a back-up for digital radiography.

  • BOX CONTENT:  50 films - Size 2: 31mm x 41mm.

TECHNICAL SPECIFICATIONS:

EXPOSURE CHART OBJECT TIME(70kV 8mA)
Maxillary Molars 0.6 Sec
  Bicuspids 0.5 Sec
  Cuspids 0.4 Sec
  Incisors 0.3 Sec
     
Mandibular Molars 0.5 Sec
  Bicuspids 0.4 Sec
  Cuspids 0.3 Sec
  Incisors 0.3 Sec


INSTRUCTIONS FOR USE:

STEP 1:

We suggest to disinfect the film before use. After exposure to x-rays , and holding ECO 30 up -right , open the liquid pouch by rolling it up. It is important to squeeze the pouch to its extremity, ensuring that all the monobath travels to the opposite film end, then un-roll it.

STEP 2:

Start agitating by sliding the fingers from the top all way down to the bottom of the film, repeating this movement for 50 secs/1 minute

IT IS IMPORTANT TO AGITATE : CONSTANTLY, FOR 50 SECS AND IMMEDIATELY AFTER THE MONOBATH POUCH HAS BEEN OPENED, otherwise image may result spotted.

STEP 3:

When development and fixation are complete, turn the film upside down, pushing the monobath back into its original place. Open film by prising apart, remove the film and rinse it under water , even by sliding the fingers on its surface to remove all the monobath residual, otherwise the picture may turn yellow

PACKAGING:      Pack of 50 Films



Write a review

Note: HTML is not translated!
    Bad           Good