Coltene Solocem Transparent

Coltene Solocem Transparent

₹4,050.00 ₹5,500.00 -26%
Product Code: COL-S
Availability: In Stock

Available Options

Coltene Solocem Transparent

  • Easy to use and time saving
  • High bonding strengths without additional adhesive
  • Low shrinkage
  • Antibacterial zinc oxide
  • High radiopacity

Easy and fast application

SoloCem saves you time without having to forego reliable bonding. MDP and 4-MET(A) monomers ensure good bonding values on a range of different materials without requiring a separate adhesive. This simplified form of application reduces the risk of potential error sources which could affect the bond and thus the quality of the entire restoration.

  • Self-adhesive properties
  • Fluorescent
  • Automix syringe and ready-to-use mixing tips
  • Intraoral processing time of approx. 60 seconds
  • Easy removal of excess material (after light curing for 3 seconds)

Description

Secure cementing does not depend on the number of working steps. Self-adhesive SoloCem achieves reliable values – with no additional bonding. This is the result of monomers contained and the composite-like formulation. The convenient automix syringe and the ready-to-use mixing tips offer a simple and time-saving application of SoloCem.

Indications

The easy handling of SoloCem offers advantages in a number of indications. You can count on the self-adhesive properties of SoloCem for the permanent cementation of:

  • Crowns (ceramic, metal, composite)
  • Bridges (ceramic, metal, composite)
  • Inlays (ceramic, metal, composite)
  • Onlays (ceramic, metal, composite)
  • All types of endodontic posts
  • Implant abutments (zirconium oxide and titanium) 

 

Key Specifications

Composition

  • Methacrylates
  • Zinc oxide
  • Dental glass

TECHNICAL SPECIFICATIONS:

Flexural strength115 Mpa
Compressive strength190 Mpa
Radiopacity4 mm Al / mm

Packaging

Coltene Solocem Transparent - Refill 2.5ml/5g Syringe:

  • 1 x 2.5ml syringe / 5g

Coltene Solocem Transparent - Trial Kit 5ml / 10.5g Syringe:

  • 1 x 5ml Syringe / 10.5g

Direction to Use

Working Time

Working time is dependent on temperature. The time will decrease with higher temperatures or increase with lower temperatures. SoloCem is light-sensitive and should not be exposed to intense light, particularly surgical lighting, for long periods of time.

Interactions

Phenolic and other substances (e.g., zinc oxide eugenol) that inhibit polymerisation must not come into contact with SoloCem.

Application

Tooth isolation: A dry working area is the basis for good results. The use of a dental dam is recommended

1. Post cementation

Note: Preparation of the working field will result in an optimal and efficient procedure

1.1 Select a suitable root post system (e.g., ParaPost® Fiber Lux™, ParaPost® Taper Lux™)

1.2 Prepare the root canal according to the manufacturer’s instructions for use

1.3 Apply SoloCem

Remove the safety cap or mixing tip. Squeeze some of the material onto a paper towel until the base and catalyst flow evenly from the opening. This will ensure a uniform mixture

1.3.2 Wipe the opening with a paper towel. Replace the mixing tip and give it a ¼-turn (90°) clockwise. Squeeze out the material and discard it until a uniform, homogeneous paste flows out. Caution: Do not dry out the dentin

1.3.3 Apply SoloCem directly into the prepared root canal using the syringe with the brown, short, super fine

If desired, the cement can also be applied in the canal using a lentulo spiral

1.3.4 Apply the cement on the root post or directly into the root canal and position the post in the root canal, applying slight pressure. Remove excess material. Use disinfectant to clean off the mixing tip (do not remove it)

1.3.5 The SoloCem material can be light-cured for 30 s to accelerate polymerisation or to reduce the inhibition layer

2. Cementing crowns, bridges, inlays, onlays

2.1 Pre-treat the inner restoration site/contact surfaces

2.1.1 Always pre-treat the restoration contact surfaces according to the manufacturer’s instructions

2.2 Apply SoloCem restoration cement

2.2.1 Remove the safety cap or mixing tip. Squeeze some of the material onto a paper towel until the base and catalyst flow evenly from the opening. This will ensure a uniform mixture

2.2.2 Wipe the opening with a paper towel. Replace the mixing tip and give it a ¼-turn (90°) clockwise. Squeeze out the material and discard it until a uniform, homogeneous paste flows out. Caution: Do not dry out the dentin

2.2.3 Apply SoloCem directly onto the inner surfaces of the restoration and/or preparation (for concave forms in order to prevent air pockets), where required. 2.2.4 Next, position the restoration, applying slight pressure. After use, disinfect the mixing tip with disinfectant, but do not remove it

2.2.5 Remove excess (e.g., with a brush or spatula) and hold the restoration in position by applying increased pressure. Note: Remove the remaining excess with a fine spatula or another suitable instrument while the restoration is held in position. The use of matrices, wedges, dental dam, etc. is intended to guarantee that no cement can flow into the sulcus and approximal area, as this can only be removed with difficulty after curing. The excess can no longer be removed once SoloCem attains a gelatinous consistency

2.2.6 The material can be light-cured for 20 s per side/ surface (where layer thickness is 2 mm) to accelerate polymerisation or to reduce the inhibition layer. Excess can be removed after brief (3 s) polymerisation or until the chemical curing allows a removal. Use disinfectant to clean off the mixing tip but do not remove it

3. Cementing on implant abutments

3.1 Pre-treat the inner restoration site/contact surfaces

3.1.1 Always condition the contact surfaces of the restoration according to the manufacturer’s instructions

3.2 Apply SoloCem cement on implant abutments

3.2.1 Remove the safety cap or mixing tip. Squeeze some of the material onto a paper towel until the base and catalyst flow evenly from the opening. This will ensure a uniform mixture

3.2.2 Wipe the opening with a paper towel. Replace the mixing tip and give it a ¼-turn (90°) clockwise. Squeeze out the material and discard it until a uniform, homogeneous paste flows out

3.2.3 Apply SoloCem directly to the inner surfaces of the restoration (for concave forms in order to prevent air pockets) and/or on the implant abutments or stumps, where required

3.2.4 Position the restoration by applying slight pressure

3.2.5 Remove excess (e.g., with a brush or spatula ) and hold the restoration in position by applying increased pressure.

Note: Remove the remaining excess with a fine spatula or another suitable instrument while the restoration is held in position. The use of matrices, wedges, dental dam, etc. is intended to guarantee that no SoloCem can flow into the sulcus and approximal area, as this can only be removed with difficulty after curing. The excess can no longer be removed once SoloCem attains a gelatinous consistency. Excess can be removed after brief (3 s) polymerisation or until the chemical curing allows a removal. Use disinfectant to clean off the mixing tip but do not remove it

3.2.6 The material can be light-cured for approximately 20 s per side/surface (where layer thickness is 2 mm) to accelerate polymerisation or to reduce the inhibition layer.

Write a review

Note: HTML is not translated!
    Bad           Good